House Wiring Wires: Which Size for Which Circuit

For house wiring, use 1–1.5 sq mm for lights and fans, 2.5 sq mm for normal sockets, 4 sq mm for AC, geyser and kitchen power points, and 6 sq mm or more for the main line, as typical sizes your electrician confirms by load and run length. Buy PVC-insulated copper wire to IS 694, FR or FRLS grade.

WhatsApp
Coils of electrical wire hanging on a wall
Electricals

How we supply it: Wires and cables are arranged through a partner electrical dealer who quotes, supplies and bills them and pays us a referral commission. Send your electrician's load list; the dealer supplies coils by size, timed for conduit and wiring after the slab and before plastering.

Also calledhouse wire, electrical wire, copper wire, FRLS wire, wiring cable
Tamilவயர்
StandardIS 694 PVC-insulated cables, IS 732 wiring practice

In one line: House wire is single-core, multi-strand copper conductor insulated with PVC or a low-smoke, halogen-free compound, drawn through conduits to carry power from the distribution board to each point.

Wire size by circuit

Typical copper wire sizes for house circuits (your electrician sizes each by load and run length)
CircuitTypical copper sizeTypical MCB
Lights and fans1–1.5 sq mm6–10 A
Normal socket circuits2.5 sq mm16 A
16 A points: washing machine, fridge, oven2.5–4 sq mm16–20 A
Split AC, 1.5 ton2.5 sq mm short runs, 4 sq mm long runs16–20 A, C curve
Geyser4 sq mm20 A
Main or sub-main to the board6–10 sq mm or moreAs per load

Next question: Which insulation grade? More

What house wire is

House wire is single-core, multi-strand copper conductor insulated with PVC or a low-smoke, halogen-free compound, drawn through conduits to carry power from the distribution board to each point. PVC-insulated wiring cables are covered by IS 694, and wiring practice by IS 732.

Each circuit runs three wires: phase, neutral and earth. Keep one colour scheme through the house, such as red or brown for phase, black or blue for neutral and green or green-yellow for earth.

Next question: How much wire do I need? More

FR, FRLS or HFFR?

Insulation grades compared
GradeWhat it addsWhere it makes sense
FR (flame retardant)Resists spreading flameBasic minimum
FRLS (flame retardant, low smoke)Less smoke when burningHomes, the usual choice
HFFR (halogen-free flame retardant)No corrosive halogen gasesEscape routes, data rooms, premium homes
FRLS copper wire to IS 694 for a house; HFFR if you want the extra margin in a fire.

Next question: How do I check what I bought? More

Estimating coils

Typical estimate: each run carries phase, neutral and earth, so wire length is about three times the conduit length, plus 10%.

  • House wire is sold in 90 m coils
  • A 30 m conduit run needs about 99 m of wire, a little over one coil
  • Order by size from your electrician's list; leftover coils of the wrong size are wasted money

Next question: Which breakers protect these circuits? More

Checks on wire coils

  1. The coil label should show IS 694, the ISI mark with licence number, size, FR or FRLS grade and length.
  2. Scrape a strand: it should be copper right through, not silver-grey aluminium under a copper skin.
  3. Count the strands on a few coils of the same size; they should match.
  4. The insulation should be even, with size and grade printed along it.
  5. Before handover, ask the electrician for an insulation-resistance (megger) test record.

Next question: How should coils be kept? More

Storing coils on site

  • Keep coils boxed in a dry, locked room.
  • Turn the coil to pay wire out rather than pulling it straight, to avoid kinks.
  • Label sizes so 1.5 and 2.5 sq mm coils are not swapped.

Next question: Which switches and sockets? More

Wiring mistakes

  • 1.5 sq mm wire on AC or geyser circuits.
  • Overfilled conduits that run hot and cannot be rewired later.
  • Joints hidden inside conduits instead of in junction boxes.
  • No separate earth wire.
  • Mixed colour codes that make later work dangerous.

Next question: Which lights go on the lighting circuits? More

Questions buyers ask

House Wires and Cables: questions buyers ask

Is 2.5 mm wire suitable for a 1.5 ton AC unit?

Often yes, for a short run on its own circuit with a suitable MCB, since a 1.5 ton split AC typically draws well within what 2.5 sq mm copper carries. For long runs, 2-ton units or hot ceiling spaces, electricians usually step up to 4 sq mm.

What are 2.5 sq mm wire used for?

Socket circuits, 16 A power points for washing machines and fridges, and short AC runs. After the 1–1.5 sq mm lighting wire, it is the size used most in Indian house wiring.

Do you use 1.5 mm or 2.5 mm cable for sockets?

2.5 sq mm for socket circuits. 1.5 sq mm is fine for lights and fans but leaves little margin on sockets where appliances get plugged in; heavy points such as geysers take 4 sq mm.

Which wire size is best for house wiring?

There is no single size: 1–1.5 sq mm for lights and fans, 2.5 sq mm for sockets, 4 sq mm for AC, geyser and heavy kitchen points, and 6 sq mm or more for the main. The electrician sizes each circuit by load and run length.

What is the difference between FR and FRLS wire?

Both are flame retardant; FRLS insulation also gives off less smoke as it burns, which matters for getting out in a fire. HFFR goes further by avoiding corrosive, toxic halogen gases.

Need House Wires and Cables with your order?

Call, WhatsApp or send the quote form with it filled in: a partner supplier quotes, supplies and bills it, and we time it with your loads.

WhatsApp